FAP544
Microprocessor control unit with 2 loop lines expandable to 4 Possibility of managing up to 128 points per loop (512 points max)
Microprocessor control unit with 2 loop lines expandable to 4 Possibility of managing up to 128 points per loop (512 points max) Self-learning of the devices in the field Graphic display 240 * 128 - 4.7 "backlit History log: 1,000 events Chronological view that can be viewed directly from display 10 programmable passwords on 3 levels 480 programmable zones, 240 groups of zones, 240 groups of points USB port for local PC connection to program via dedicated software Possibility to monitor the level of the signal / noise ratio of the sensor Real time clock integrated with buffer battery Non-volatile memory Control unit outputs: alarm, siren, fault, programmable (mains failure / exclusion) Internal buzzer Exclusion of the single point / zone Power supply: 230Vac Maximum deliverable current: 1.5A @ 24Vdc Limitation of the battery charge and control of their status Accumulator housing: 2 batteries of 12 @ 12Vdc Possibility of creating a loop of max 2 Km with shielded 2x1.5mm cable Immunity to disturbances up to 30Vm Common dialogue protocol for all control units system Dimensions: 490 (L) x 350 (H) x 145 (D) mm EN54 certified part 2 and 4 (0051-CPD-0239)
Basic configuration: 2 loop lines (class A) or 4 open lines (class B)
Maximum configuration: 4 loop lines (class A) or 8 open lines (class B)
Possibility of managing up to 128 points per loop
Point teach-in and point logic address
240*128 - 4.7 “ backlit graphic display
Event log: 1,000 events
Event history shown on display
10 passwords programmable on 3 levels
480 programmable zones
USB port for connection to local PC for programming via SW
Possibility of monitoring detector signal/noise ratio level
Built-in real time clock with buffer battery
Non-volatile memory
Alarm data saved on devices
Monitoring of the first 10 devices entering alarm status with graphic and digital time-trend visualisation
Control unit outputs: 4 [siren relay, alarm relay, malfunction relay, programmable relay (power
failure/exclusion)]
Internal buzzer
Exclusion of individual point /zone
Power supply: 230 Vac
Maximum output current: 1.5 A @ 24 Vdc
Battery charge limit and battery status check
Battery housing: 2x 12 A @ 12 Vdc batteries
Possibility of implementing at least 2 Km loop with 2 x 1.5 mm2 screened cable
Noise immunity up to 30 Vm
Communication protocol shared by all system control units
Dimensions (W x H x D): 490 x 350 x 145 mm
Certified EN54 part 2 class and part 4, No. 0051-CPD-0239